•Alerts to Hazardous RF Exposures
•Meets FCC, OSHA, and WHO Guidlines
•Visual and Audio Alarms
•Wide Radio Frequency Range
•Rugged, Professional Construction
|
SafeOne™ personal RF safety monitors are an effective and economical means to monitor the strength of electromagnetic
(RF) fields from mobile phone towers, microwave
ovens, radio and
television installations, high frequency welders, and other common workplace RF
sources between 10 and 10,000 MHz. The Personal RF Monitor is essential RF safety equipment in complying with FCC, OSHA, and other workplace rf safety requirements.
SafeOne™ personal RF safety monitors give you audio and
visual warning when the IEEE and ICNIRP limit is
exceeded on your body. It immediately alerts you to high frequency radiation fields that could be a health hazard. SafeOne™
gives an approximate value of RF
strength to help you determine how long you can stay in the radiation field.
Extremely convenient to wear and use, the SafeOne™ personal RF safety monitor is the size of a cell phone and weighs under 3 ounces! It's smaller and much lighter than competing units!
Using Your SafeOne™ Personal RF Monitor
Wearing Your Monitor
The SafeOne™ personal RF monitor should be worn on the belt
with the supplied belt clip, or clipped to a harness in the included carry
pouch. Position the Personal Monitor clear
of metallic objects, such as a tool pouch. The SafeOne™ personal RF monitor should not be used with an RF protective suit.
Preparation for Use
To start using
SafeOne™ personal RF protection, simply unscrew the battery cover on the back and insert two AAA alkaline batteries, perform a functional test, and set desired alarm parameters.
No need to worry about the batteries - the SafeOne™ pocket RF monitor's batteries can last over 500 days!
The
monitor incorporates a self-test function to be used whenever the
monitor is turned on.
Interpreting Your Monitor
The SafeOne™ personal RF monitor uses a simple set of audible
and visual alarms to alert you to dangerous radio frequency (RF) fields. Those
alarms can be set for your convenience.
When SafeOne™ RF radiation monitors give an alarm, it means that your RF exposure may be above FCC, OSHA, or
ICNIRP limits. When this occurs, you should leave the area and proceed in
accordance with your company’s RF safety plan or consult the appropriate
workplace authority.
Setting Alarm / Function Features
SafeOne™ has
2 alarm levels and 3 alarm functions. All functions are controlled by pressing the SELECT pushbutton.
When SELECT is pushed there is audio and visual feedback.
The World Health Organization has established health hazard limits that are accepted in most parts of the world
as standards. In the United
States, these are standards of the FCC and
OSHA. The radiofrequency exposure, Maximum Permissable Exposure (MPE) limits are divided into two
levels, one for “General Public” use and one for persons trained to work in
high frequency radiation areas, referred to as “Occupational”.
Your RF monitor can be set to these two alarm levels.
The lower "Public" level is automatically chosen when SafeOne™ personal RF protection is turned on. To choose "Occupational", press and hold the SELECT pushbutton for more than 5 seconds.
The unit will respond with 10 long or 10 short beeps. The chosen level is
indicated by a lighted bar.
By
pushing the SELECT button momentarily, the 3 different RF safety alarm functions can be chosen:
-
Normal (one beep): In this
position the SafeOne™ personal RF safety monitor will give both
audible and visual warning, when the chosen alarm limit is exceeded.
-
Timer
(two beeps): SafeOne™ will only give visual warning,
when the chosen alarm limit is exceeded. After approximately 5 minutes SafeOne™ will beep and return to normal
position.
-
Silent
(three beeps): SafeOne™ will only give visual warning
when the chosen RF safety alarm limit is exceeded.
Maintaining Your Monitor
No
routine maintenance is needed to keep your SafeOne™
personal RF monitor in good order! Just take common sense measures to keep it clean, dry, and
secure. Calibration services are available
OUTSTANDING VALUE!
FREE - Nylon Rigger Case
FREE - Lithium Batteries
FREE - Training CD
FREE - Shipping*
|
Tower Constructors!
Job in trouble for lack of crew RF monitors?
LBA ships overnight to your job location!
|
Only $695 US*!

For orders, quotes, or tech assistance,
use our

Or
Contact Dick Hansson, dhansson@lbagroup.com
Call 800-522-4464 or 252-757-0279

Accepted
*No charge for ground shipment within the continental United States. Expedited shipping and handling will be charged extra. Duties and taxes are extra as required by destination. Offered for professional use only.

|
Suggested Research
Topics on Personal RF Protection:
Safety
equipment:
RF
personal exposure monitors ● electromagnetic radiation meters ● pocket radio
frequency safety monitors ● RF alert meter devices, ● OSHA RF radiation
exposure monitor ● Nardalert XT ● Narda Radman ● Nardalert ● RF protective
clothing
Occupational
RF hazards:
RF
burns danger ● antenna safety ● radio frequency radiation RF hazards ● rooftop RF
exposure ● human exposure to radio frequency ● electromagnetic fields ● RF safety on towers
● tower climber safety ● protection for tower workers ● industrial RF
protection ● heat sealer radio energy ● microwave oven energy exposure ● high
frequency welders ● AM FM TV radio towers ● radio communications transmitters
Regulatory
and standards:
OSHA safety
compliance ● RF hazard assessment survey ● OSHA tower safety ● OSHA RF
radiation MPE safety standards ● FCC radio frequency radiation RF MPE exposure
regulations ● WHO ICNIRP standards |
|
Personal RF Monitor Value • OSHA RF Radiation Alarm • New Tower Tech RF Monitor • OSHA RF Exposure Alarm • Buy OSHA RF Alarms Here • Personal RF Alarm Savings • Buy OSHA RF Monitors Here • OSHA RF Safety Monitor • OSHA Safety Monitor
|
|
Search our site.
Find the product/service you need.
|

|
3400 Tupper Drive
Greenville, North Carolina 27834
800-522-4464 / 252-757-0279 / Fax 252-752-9155
Email:
Copyright 2009. LBA Group, Inc.
All Rights Reserved.