AM CoLoPole™ Specifications

 

AM CoLoPole™ Specifications

Short summaries of specifications pertinent to typical CoLoPole™ configurations are shown below.  CoLoPoles™ are furnished in "Standard" and "Heavy-Duty" configurations.  Both are constructed using utility-grade components for long life and resistance to adverse environmental conditions.  All fiberglass components are treated with anti-UV coatings.  Dissimilar metal contacts are avoided to minimize intermodulation in a communications RF environment.

  Standard
CLP-311-200
Heavy-Duty
CLP-351-200
Frequency Range: 500-2500 khz 500-2500 khz
Power Rating: 5,000 watts 25,000 watts
Impedance (adjustable*): 10-300+/-j 350 ohms 10-300+/-j 350 ohms
Lightning Protection: DC ground DC ground
Windload (100 mph): 300# (135 Kg) 600# (270 Kg)
Download: 500# (225 Kg) 700# (315 Kg)
Weight: 125# (56 Kg) 200# (90 Kg)
Insulation: Fiberglass Fiberglass/ceramic
 

The configurations above are typical of a 200-foot CoLoPole™, widely used in AM colocation systems.  However, systems of any length and power rating can be supplied.  Please consult LBA for customized specifications*.

*Specifications are approximate and subject to change without notice.